ISO 9001CEEuroventEN 1886 Designed & manufactured in İzmir, Türkiye

Language
info@technogen-hvac.com +90 532 201 00 11 Request a quote
Heat recovery family
SuperairZephyrSenseAir

Superair

Ceiling-type heat recovery units with Eurovent-certified plate heat exchangers.

Technogen Superair — Heat Recovery Units
  • 0airflow models
  • 800–6,000m³/hairflow range
  • 0mmdouble-skin insulation
  • 0Vsingle-phase supply

01Overview

Fresh air in. Energy
kept inside.

Superair heat recovery units were developed by Technogen to meet growing demands for energy efficiency and indoor air quality — exhausting stale air while supplying fresh air, and transferring heat between the two through a plate heat exchanger.

They suit offices, hotels, restaurants, hospitals, cinemas, exhibition halls and residential buildings.

Eurovent

Certified heat exchangers

Eurovent-certified cross-flow plate heat exchangers deliver a high level of heat recovery.

Plug fans

Low-noise plug fans

Backward-curved plug fans on directly coupled AC motors for low energy use and low noise.

25 mm

Double-skin insulation

25 mm flame-retardant double-skin insulation throughout the casing.

G4 · M5

Two-stage filtration

G4 filters in both fresh-air and exhaust streams, with ePM10 50% (M5) class filters.

Options

Configurable options

Electric heaters, hot-water coils and silencers adapt each unit to the project.

BMS

Controls & BMS

Optional digital room control panels and integration with building management systems.

02How it works

Two airstreams.
Zero mixing.

Superair recovers heat from exhaust air through a cross-flow plate exchanger, so fresh air arrives pre-tempered.

  1. 01

    Extract

    Stale air is drawn from the space and passes through the plate exchanger.

  2. 02

    Exchange

    Heat transfers across the thin plates — the two airstreams never mix.

  3. 03

    Supply

    Filtered fresh air enters the space already pre-tempered.

03Range

Nine models.
One family.

From compact apartments to large projects — Superair spans 800 to 6,000 m³/h across nine airflow models.

Airflow≈ 471–3,531 CFM800 – 6,000 m³/h
TEVHR-800 · 865 m³/h · 57 dB(A)TEVHR-6000 · 6,000 m³/h · 59 dB(A)
07,000
Fan motor power270 – 1,600 W
02,000

Ranges across the nine Superair models. Data for every model is in the technical catalogue.

04Specifications

Technical overview.

Type
Ceiling-type heat recovery unit
Models
9 airflow capacity models
Airflow
800 – 6,000 m³/h (≈ 470–3,530 CFM)
Heat exchanger
Eurovent-certified cross-flow plate
Fans
Backward-curved plug fans, directly coupled AC motors
Fan motor power
270 – 1,600 W
Noise
57 dB(A) (TEVHR-800) · 59 dB(A) (TEVHR-6000)
Insulation
25 mm flame-retardant double-skin
Filtration
G4 in fresh-air and exhaust streams · ePM10 50% (M5)
Options
Electric heater, hot-water coil, silencer
Controls
Optional digital room control panel, BMS integration
Electrical
230 V / 50 Hz, single-phase
Service
User-friendly service doors, modular structure

05Model data

Catalogue figures,
at a glance.

As published in the Superair technical catalogue.

Performance

ModelAirflowm³/hSound leveldB(A)Fan powerWMax. currentA
TEVHR-800865572701.2
TEVHR-10001,210593101.4
TEVHR-15001,500624502.0
TEVHR-20002,100504502.0
TEVHR-25003,150557503.5
TEVHR-30003,150557503.5
TEVHR-40004,400559404.8
TEVHR-50006,000551,3006.0
TEVHR-60006,000591,6008.0

Airflow and fan power at 0 Pa external static pressure. Sound level at 250 Hz, 1.5 m from the unit. Power supply 1~230 V 50 Hz. Every model comes with rectangular (R) or circular (C) duct connections; the figures are the same.

Dimensions

ModelWidthmmDepthmmHeightmmRectangular duct (R)mmCircular duct Ø (C)mmWeightkg
TEVHR-8006761,110315220 × 22020060
TEVHR-10008381,262374220 × 22020075
TEVHR-15008381,362424270 × 27025085
TEVHR-20009381,498474320 × 320300110
TEVHR-25001,0601,894544370 × 370355135
TEVHR-30001,0601,894544370 × 370355135
TEVHR-40001,2032,151633450 × 450400160
TEVHR-50001,2032,151633450 × 450450190
TEVHR-60001,2242,151672500 × 500500210

Width, depth and height are dimensions A, B and C of the catalogue drawing.

Download catalogue →

06Fan curves

Airflow
against pressure.

Redrawn from the curves in the Superair technical catalogue. Move along a curve to read it.

010020030040002004006008001,000 Airflow (m³/h) Pressure (Pa)
020040060005001,0001,500 Airflow (m³/h) Pressure (Pa)
020040060080005001,0001,500 Airflow (m³/h) Pressure (Pa)
020040060005001,0001,5002,0002,500 Airflow (m³/h) Pressure (Pa)
010020030040050001,0002,0003,000 Airflow (m³/h) Pressure (Pa)
010020030040050001,0002,0003,0004,000 Airflow (m³/h) Pressure (Pa)
010020030040050001,0002,0003,0004,000 Airflow (m³/h) Pressure (Pa)
020040060001,0002,0003,0004,0005,000 Airflow (m³/h) Pressure (Pa)
020040060080002,0004,0006,000 Airflow (m³/h) Pressure (Pa)

Redrawn from the fan curves on pages 8–25 of the SuperAir technical catalogue. The R (rectangular duct) and C (circular duct) versions of each model share the same curve.

Specify Superair for
your next project.

Share your drawings or requirements and our engineering team will come back with a tailored Superair selection.