Tested before it ships
Coils are pressure-tested at 20 bar. HEROS casings are tested to EN 1886: strength class D2, casing air leakage class L1.
Technogen designs, builds and tests energy-efficient air handling, heat recovery and climate systems.
Our vision
Our goal is to become the most preferred brand in heating, cooling and ventilation, consistently providing our customers with Smart Solutions for HVAC.
01Engineering
Our R&D team designs every product line, and we build it at our factory in Torbalı. These are the tests and tools behind the numbers in our catalogues.
Coils are pressure-tested at 20 bar. HEROS casings are tested to EN 1886: strength class D2, casing air leakage class L1.
HEROS comes in 62 casing sizes built around standard filter dimensions, and each of the 19 module types fits every size.
Fan coil and terminal unit tables give the conditions behind each figure, such as 27 °C DB / 50% RH room air and 7/12 °C chilled water.
Our engineers size HEROS units in Technogen’s AHU selection software, which produces DXF drawings and technical documents for each unit.
02How we work
Every Technogen system follows the same path: designed in-house, built from certified components and tested before it ships.
Products are developed by the Technogen R&D team, with energy efficiency at the core of the design process.
Long-life components that comply with international quality standards.
Standardised, ISO 9001-certified production processes in İzmir.
Factory testing, from coils pressure-tested at 20 bar to EN 1886-compliant casings.
Our engineers size the unit for your project and send the performance data and documentation.
03Quality & certifications
Each one covers something different: how we run production, what every unit declares, what an independent body verifies, and how casings are tested.
Certified quality management for our production processes.
CE marking: units meet the EU health, safety and environmental requirements that apply to them.
Certified performance for HEROS, Superair heat exchangers and the Zenair design.
Air-handling-unit casing performance for HEROS.
Product testing standards
Zenair fan coils tested in compliance.
Zenair fan coils tested in compliance.
Zenair fan coils tested in compliance.
Zenair fan coils tested in compliance.
04Sustainability
A ventilation unit’s footprint is decided in four places: how it is built, how much heat it gets back, what it draws to run, and what it lets out.
See the CO₂ worked example →
returned to the supply air at 10,000 m³/h, with −5 °C outside, 22 °C inside and 84% recovery. That is heat the boiler or heat pump does not have to produce.
Build
50mm
HEROS panels are double-skinned and filled with 70 kg/m³ rock wool. Gaskets keep the skins apart, so no metal runs straight through, and casings test to EN 1886 leakage class L1.
Recover
90%
Heat recovery is standard on Superair, SenseAir, Zephyr and every Techno-Pool unit. Zephyr and SenseAir return up to 90% of the heat in the outgoing air, and a HEROS rotary wheel up to 80%.
Run
0.9W
A Zephyr room unit draws 0.9 W in night mode and 5.9 W at full speed. SenseAir residential heat recovery is rated energy class A+.
Release
>95%
Tecology’s electrostatic cells capture over 95% of fine grease and smoke. The cells wash clean and go back in, and the carbon cartridges are recharged instead of replaced.
06Head office & production
Tell us the application, the airflow and any space limits. An engineer replies with a unit selection and the documentation.