Designed & manufactured in İzmir, Türkiye

Language
info@technogen-hvac.com +90 532 201 00 11 Request a quote

Aurater

Air terminal units with quiet radial fans and factory-tested coils.

Technogen Aurater, Air Terminal Units
  • 101.39kWmax. heating capacity
  • 39.51kWmax. cooling capacity
  • 150Paexternal static pressure
  • 20barcoil pressure test

01Overview

36 dB(A) at low speed,
coils tested at 20 bar.

Aurater air terminal units have a galvanised steel body, radial fans, and coils made from seamless copper tube with aluminium fins. Each coil is pressure-tested at 20 bar.

Cooling runs from 9.79 to 39.51 kW and heating up to 101.39 kW, for commercial and residential projects.

20 bar

Factory-tested coils

Seamless copper tubes and aluminium fins, each coil tested at 20 bar.

36 dB(A)

Quiet radial fans

High-efficiency radial fans, with 36–43 dB(A) at low speed.

Galvanised

Corrosion-resistant body

Galvanised steel construction with sound and thermal insulation.

150 Pa

Wide pressure range

Operates across external static pressures up to 150 Pa.

Optional

Electric heater

Stainless-steel resistors and halogen-free cables for safe operation.

3R · 4R · 5R

Coil & pipe options

2-pipe and 4-pipe versions with 3-, 4- and 5-row coils.

02Performance

Performance across
the range.

Ranges across the series. At low speed every model stays between 36 and 43 dB(A).

Cooling capacity9.79 – 39.51 kW
050
Heating capacity10.43 – 101.39 kW
0120
External static pressureUp to 150 Pa
0200
Sound pressure, low speed36 – 43 dB(A)
060
Sound pressure, high speed50 – 54 dB(A)
060

Ranges across the Aurater series. Per-model data is in the technical catalogue.

03Specifications

Technical overview.

Body
Corrosion-resistant galvanised steel, sound and thermal insulation
Fans
High-efficiency, quiet radial fans
Coils
Seamless copper tubes, aluminium fins; 3R, 4R, 5R options; factory-tested at 20 bar
Systems
2-pipe and 4-pipe versions
Cooling capacity
9.79 – 39.51 kW
Heating capacity
10.43 – 101.39 kW
External static pressure
Up to 150 Pa
Sound pressure
36 – 43 dB(A) low speed · 50 – 54 dB(A) high speed
Electric heater
Optional; stainless-steel resistors, halogen-free cables
Accessories
Digital room thermostat, washable metal filter, G3 synthetic filter, plenum box
Electrical
230 V / 50 Hz

04Model data

Figures from
the catalogue.

As published in the Aurater technical catalogue.

2-pipe

ModelAirflow (high speed)m³/hTotal cooling capacitykWSensible cooling capacitykWHeating capacity, 70/60 °CkWHeating capacity, 90/70 °CkWSound pressure (high speed)dB(A)Power input (high speed)WDimensions (H × W × D)mmNet weightkg
3051,7369.967.4022.6210.3851271335 × 1,157 × 55840.1
4051,69512.148.4024.8833.7451264335 × 1,157 × 55842.4
5051,65113.488.9725.7635.1651.5258335 × 1,157 × 55844.7
3102,10812.559.2027.9137.5853358385 × 1,242 × 55845.1
4102,07715.2610.4630.7741.8353350385 × 1,242 × 55848
5102,03916.9311.2031.9943.7553.5344385 × 1,242 × 55850.7
3152,44215.0910.8732.6244.0350405385 × 1,412 × 58952.3
4152,41418.1812.3435.9648.9850.5399385 × 1,412 × 58955.6
5152,38420.1413.2537.5351.4850.5393385 × 1,412 × 58958.6
3203,48921.7315.5746.5262.7854549335 × 2,143 × 55880
4203,41624.9117.1350.5568.6454531335 × 2,143 × 55884.9
5203,33628.1218.5152.4571.7654.5521335 × 2,143 × 55888.7
3254,24027.1319.3357.6577.9553.5723435 × 2,143 × 55887.7
4254,19131.1621.3262.7985.4653.5708435 × 2,143 × 55893.9
5254,13235.3723.1965.4789.8253.5697435 × 2,143 × 558101.7
3304,85929.8721.4764.2186.6453806435 × 2,143 × 58992.4
4304,79634.5523.8370.4795.7453.5790435 × 2,143 × 58998.6
5304,73039.5126.0674.01101.3954776435 × 2,143 × 589106.4

High fan speed, G2 filter, 50 Pa external static pressure, 230 V 50 Hz. Cooling: room 27 °C DB / 50% RH, chilled water 7/12 °C. Heating: room 20 °C DB, hot water 70/60 °C or 90/70 °C. Sound pressure at 1 m (Q = 1).

4-pipe

ModelAirflow (high speed)m³/hTotal cooling capacitykWSensible cooling capacitykWHeating coil, 70/60 °CkWHeating coil, 90/70 °CkWSound pressure (high speed)dB(A)Power input (high speed)WDimensions (H × W × D)mmWeightkg
3051,6959.797.2710.4313.6951264335 × 1,157 × 55845.3
4051,65011.908.2110.2613.4651.5258335 × 1,157 × 55847.6
3102,07712.429.0913.1617.3653350385 × 1,242 × 55851.6
4102,03815.0410.3013.0117.1453.5343385 × 1,242 × 55854.5
3152,41414.9610.7715.4720.4650.5399385 × 1,412 × 58953.9
4152,38418.0112.2115.3620.2950.5393385 × 1,412 × 58963.3
3203,41421.4015.3221.7428.6954532335 × 2,143 × 55890.5
4203,33424.4616.7921.4328.2554.5520335 × 2,143 × 55895.4
3254,19026.9119.1527.8736.9753.5708435 × 2,143 × 558100.2
4254,13030.8121.0727.6236.6053.5696435 × 2,143 × 558106.4
3304,79629.6021.2630.2139.9953.5790435 × 2,143 × 589104.9
4304,72934.1823.5629.9539.6354776435 × 2,143 × 589111.1

High fan speed, G2 filter, 50 Pa external static pressure, 230 V 50 Hz. Cooling: room 27 °C DB / 50% RH, chilled water 7/12 °C. Heating: room 20 °C DB, hot water 70/60 °C or 90/70 °C. Sound pressure at 1 m (Q = 1). Heating figures are for the separate heating coil.

Download catalogue →

Send us
your drawings.

Tell us the airflow, the application and any space limits. We will size the Aurater unit and send the performance data.