Flexible modular design
62 standard sizes, each available with any of the 19 module types.
Modular air handling units for hygienic, comfort and industrial applications.
01Overview
Technogen HEROS air handling units are designed by our R&D team for hygienic, comfort and industrial applications. The 62 casing sizes follow standard filter dimensions, and each of the 19 module types fits every size.
Specialised panel and body construction minimises thermal bridging, while the modular structure makes transport, installation, maintenance and dismantling straightforward.
62 standard sizes, each available with any of the 19 module types.
50 mm panels filled with 70 kg/m³ rock wool. Tested to EN 1886: strength class D2, casing air leakage class L1.
Panel, bag, compact, activated-carbon and HEPA filters for comfort, hygienic and clean environments.
Rotary wheel up to 80%, plate exchanger 70%, or a glycol circuit for fully separated airstreams.
EC plug fans with VFD integration, on spring isolators.
Optional building-management integration and remote monitoring.
Strength class D2, casing air leakage class L1.
Certifies how Technogen documents and audits its production.
CE marking: the unit meets the EU health, safety and environmental requirements that apply to it.
Independently verified performance ratings.
02Anatomy
Select a point on the unit to see how HEROS is put together.
50 mm rock-wool insulated panels, with panel and body construction designed to minimise thermal bridging and noise breakout.
Access doors and inspection windows give service teams direct, safe access to fans, filters and coils.
Clearly marked heating and cooling coil connections for fast, error-free installation on site.
Supply and extract openings with dampers, configured to the airflow arrangement of each project.
Units are built from modular sections on a base frame for easy transport, installation and dismantling.
03Configure
Start from a typical arrangement, then add or remove modules. Send the airflow sequence to our engineers for a full selection.
Representative selection. The full set of 19 HEROS functional modules, with dimensions and performance for every size, is in the technical catalogue.
04Heat recovery
HEROS takes rotary, plate or glycol-circuit heat recovery, chosen for each project's hygiene and efficiency requirements.
A slowly rotating heat wheel passes alternately through the extract and supply airstreams. It stores energy from the outgoing air and releases it into the incoming air.
Compact, with high recovery in a small footprint.
Humidity transfer is around 40% with a condensation rotor, up to 60% with silica-gel coating and up to 80% with zeolite coating. A sweeping cell turns return air back before it can mix with fresh air.
Thin plates form separate channels for the two airstreams, which exchange heat across the plate surfaces without mixing.
No moving parts and simple maintenance. A natural fit where airstream separation matters.
An optional bypass damper gives free cooling; a drain pan collects condensate on the exhaust side.
Separate coils in the extract and supply airstreams are linked by a pumped water–glycol loop that carries heat between them.
Supply and extract sections can be installed apart, with no contact between the airstreams.
05Construction
Materials, components and options as specified in the HEROS technical catalogue.
Three standard silencer lengths. Noise reduction in dB per octave band, as published in the HEROS catalogue.
| Length | 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | 8000 Hz |
|---|---|---|---|---|---|---|---|---|
| 600 mm | 4 | 8 | 15 | 15 | 17 | 12 | 9 | 6 |
| 900 mm | 6 | 12 | 22 | 22 | 24 | 23 | 13 | 9 |
| 1200 mm | 7 | 15 | 27 | 28 | 29 | 29 | 19 | 12 |
06Specifications
07Model data
As published in the HEROS technical catalogue.
| Model | Height (H)mm | Width (W)mm | Cooling coilmm | DX coilmm | Plate heat recoverymm | Mixing box with dampermm | Air inlet / outletmm |
|---|---|---|---|---|---|---|---|
| HRS 4 X 4 | 912 | 712 | 559 | 559 | 1,018 | 1,171 | 559 |
| HRS 4 X 6 | 912 | 1,018 | 559 | 559 | 1,018 | 1,171 | 559 |
| HRS 4 X 8 | 912 | 1,324 | 559 | 559 | 1,018 | 1,171 | 559 |
| HRS 6 X 6 | 1,218 | 1,018 | 559 | 559 | 1,018 | 1,171 | 559 |
| HRS 6 X 8 | 1,218 | 1,324 | 559 | 559 | 1,018 | 1,171 | 559 |
| HRS 6 X 10 | 1,218 | 1,630 | 559 | 559 | 1,018 | 1,171 | 559 |
| HRS 6 X 12 | 1,218 | 1,936 | 559 | 559 | 1,018 | 1,171 | 559 |
| HRS 8 X 8 | 1,524 | 1,324 | 559 | 712 | 1,171 | 1,171 | 559 |
| HRS 8 X 10 | 1,524 | 1,630 | 559 | 712 | 1,018 | 1,171 | 559 |
| HRS 8 X 12 | 1,524 | 1,936 | 559 | 712 | 1,171 | 1,171 | 559 |
| HRS 8 X 16 | 1,524 | 2,548 | 559 | 712 | 1,477 | 1,171 | 559 |
| HRS 10 X 10 | 1,830 | 1,630 | 559 | 712 | 1,477 | 1,630 | 712 |
| HRS 10 X 12 | 1,830 | 1,936 | 559 | 712 | 1,477 | 1,324 | 712 |
| HRS 10 X 14 | 1,830 | 2,242 | 559 | 712 | 1,171 | 1,324 | 712 |
| HRS 10 X 16 | 1,830 | 2,548 | 559 | 712 | 1,171 | 1,324 | 712 |
| HRS 10 X 18 | 1,830 | 2,854 | 559 | 712 | 1,171 | 1,324 | 712 |
| HRS 10 X 20 | 1,830 | 3,160 | 559 | 712 | 1,477 | 1,630 | 712 |
| HRS 12 X 12 | 2,136 | 1,936 | 559 | 712 | 1,783 | 1,936 | 1,018 |
| HRS 12 X 14 | 2,136 | 2,242 | 559 | 712 | 1,477 | 1,783 | 1,018 |
| HRS 12 X 16 | 2,136 | 2,548 | 559 | 712 | 1,477 | 1,630 | 1,018 |
| HRS 12 X 18 | 2,136 | 2,854 | 559 | 712 | 1,477 | 1,630 | 1,018 |
| HRS 12 X 20 | 2,136 | 3,160 | 559 | 712 | 1,783 | 2,242 | 1,018 |
| HRS 12 X 22 | 2,136 | 3,466 | 559 | 712 | 1,783 | 1,936 | 1,018 |
| HRS 12 X 24 | 2,136 | 3,772 | 559 | 712 | 1,171 | 1,936 | 1,018 |
| HRS 14 X 14 | 2,442 | 2,242 | 712 | 712 | 1,783 | 2,395 | 1,171 |
| HRS 14 X 16 | 2,442 | 2,548 | 712 | 712 | 1,783 | 2,395 | 1,171 |
| HRS 14 X 18 | 2,442 | 2,854 | 712 | 712 | 1,783 | 2,242 | 1,018 |
| HRS 14 X 20 | 2,442 | 3,160 | 712 | 712 | 1,783 | 1,936 | 1,018 |
| HRS 14 X 22 | 2,442 | 3,466 | 712 | 712 | 1,783 | 1,936 | 1,018 |
| HRS 14 X 24 | 2,442 | 3,772 | 712 | 712 | 1,783 | 1,936 | 1,018 |
| HRS 14 X 26 | 2,442 | 4,078 | 712 | 712 | 1,783 | 1,936 | 1,018 |
| HRS 14 X 28 | 2,442 | 4,384 | 712 | 712 | 1,783 | 1,936 | 1,018 |
| HRS 16 X 16 | 2,748 | 2,548 | 712 | 712 | 2,548 | 2,548 | 1,324 |
| HRS 16 X 18 | 2,748 | 2,854 | 712 | 712 | 1,783 | 2,395 | 1,171 |
| HRS 16 X 20 | 2,748 | 3,160 | 712 | 712 | 1,477 | 2,242 | 1,018 |
| HRS 16 X 22 | 2,748 | 3,466 | 712 | 712 | 1,783 | 2,242 | 1,018 |
| HRS 16 X 24 | 2,748 | 3,772 | 712 | 712 | 1,783 | 1,936 | 1,018 |
| HRS 16 X 26 | 2,748 | 4,078 | 712 | 712 | 1,783 | 2,242 | 1,018 |
| HRS 16 X 28 | 2,748 | 4,384 | 712 | 712 | 1,783 | 2,242 | 1,018 |
| HRS 16 X 30 | 2,748 | 4,690 | 712 | 712 | 1,783 | 2,242 | 1,018 |
| HRS 16 X 32 | 2,748 | 4,996 | 712 | 712 | 1,783 | 2,242 | 1,018 |
| HRS 18 X 18 | 3,054 | 2,854 | 712 | 712 | 4,690 | 3,619 | 1,783 |
| HRS 18 X 20 | 3,054 | 3,160 | 712 | 712 | 3,160 | 3,160 | 1,630 |
| HRS 18 X 22 | 3,054 | 3,466 | 712 | 712 | 3,160 | 3,007 | 1,477 |
| HRS 18 X 24 | 3,054 | 3,772 | 712 | 712 | 2,548 | 2,854 | 1,324 |
| HRS 18 X 26 | 3,054 | 4,078 | 712 | 712 | 2,089 | 2,548 | 1,324 |
| HRS 18 X 28 | 3,054 | 4,384 | 712 | 712 | 1,783 | 2,395 | 1,171 |
| HRS 18 X 30 | 3,054 | 4,690 | 712 | 712 | 2,089 | 2,395 | 1,171 |
| HRS 18 X 32 | 3,054 | 4,996 | 712 | 712 | 1,783 | 2,395 | 1,171 |
| HRS 18 X 34 | 3,054 | 5,302 | 712 | 712 | 1,783 | 2,395 | 1,171 |
| HRS 18 X 36 | 3,054 | 5,608 | 712 | 712 | 1,783 | 2,395 | 1,171 |
| HRS 20 X 20 | 3,360 | 3,160 | 712 | 712 | 4,690 | 3,772 | 1,936 |
| HRS 20 X 22 | 3,360 | 3,466 | 712 | 712 | 4,690 | 3,619 | 1,783 |
| HRS 20 X 24 | 3,360 | 3,772 | 712 | 712 | 4,690 | 3,160 | 1,630 |
| HRS 20 X 26 | 3,360 | 4,078 | 712 | 712 | 3,160 | 3,007 | 1,477 |
| HRS 20 X 28 | 3,360 | 4,384 | 712 | 712 | 3,160 | 2,854 | 1,324 |
| HRS 20 X 30 | 3,360 | 4,690 | 712 | 712 | 2,548 | 2,548 | 1,324 |
| HRS 20 X 32 | 3,360 | 4,996 | 712 | 712 | 2,548 | 2,548 | 1,324 |
H and W are the casing height and width. The other columns give the dimension printed under each section in the catalogue. Sections that are the same for every size: bag filter 865 (600 mm bags) or 559 (300 mm bags), panel filter 253, heating coil 406, humidifier 712, electric heater 559, silencer 865. All in mm, 50 mm panels. For quick selection only; other parameters need the selection programme.
08Downloads
Dimensions, performance data and module options for all 62 sizes.
ISO 9001 certificate, CE declaration of conformity and Eurovent documentation for tender and approval packages.
Unit sizing and performance data prepared by our engineers for your project.
Tell us the airflow, the application and any space limits. We will size the HEROS unit and send the performance data.